Customer Communication Interface
ben@ben.com
P/N: panel
Rev: 1
Sierra Proto Express
P/N:
Name: afv1-10488
Layername:
l1s
File name:
sierra.front.gbr
X:
10.1617
Y:
2.4644
Refdes:
 
Value Found:
3.900
Rule:
5.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
Circuit to circuit
Comment: "Circuits that are too close may bridge during imaging, etching, plating, or soldering processes resulting in a direct short. The circuit to circuit minimum spacing for this product is 5.800 mils. This location measures 3.900 mils."
There are 1 additional locations where this issue occurs...
Click Thumbnail on Right to see locations.
Layername:
l2g
File name:
sierra.group7.gbr
X:
5.5631
Y:
4.9242
Refdes:
 
Value Found:
4.974
Rule:
9.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
PTH to Copper
Comment: When a plated hole is too close to copper features the plated hole may short to the copper feature. The plated hole to copper feature minimum requirement for this product is 9.800 mils. This location measures 4.974 mils.
There are 42 additional locations where this issue occurs...
Click Thumbnail on Right to see locations.
Layername:
l2g
File name:
sierra.group7.gbr
X:
5.4948
Y:
4.8821
Refdes:
 
Value Found:
5.000
Rule:
9.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
PTH to Copper
Comment: When a plated hole is too close to copper features the plated hole may short to the copper feature. The plated hole to copper feature minimum requirement for this product is 9.800 mils. This location measures 5.000 mils.
There are 747 additional locations where this issue occurs...
Click Thumbnail on Right to see locations.
Layername:
l2g
File name:
sierra.group7.gbr
X:
1.2525
Y:
6.1880
Refdes:
 
Value Found:
5.000
Rule:
9.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
PTH to Copper
Comment: When a plated hole is too close to copper features the plated hole may short to the copper feature. The plated hole to copper feature minimum requirement for this product is 9.800 mils. This location measures 5.000 mils.
There are 11 additional locations where this issue occurs...
Click Thumbnail on Right to see locations.
Layername:
l2g
File name:
sierra.group7.gbr
X:
10.8025
Y:
4.4605
Refdes:
 
Value Found:
5.000
Rule:
9.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
PTH to Copper
Comment: When a plated hole is too close to copper features the plated hole may short to the copper feature. The plated hole to copper feature minimum requirement for this product is 9.800 mils. This location measures 5.000 mils.
There are 3 additional locations where this issue occurs...
Click Thumbnail on Right to see locations.
Layername:
l2g
File name:
sierra.group7.gbr
X:
8.1434
Y:
3.2739
Refdes:
 
Value Found:
7.497
Rule:
9.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
PTH to Copper
Comment: When a plated hole is too close to copper features the plated hole may short to the copper feature. The plated hole to copper feature minimum requirement for this product is 9.800 mils. This location measures 7.497 mils.
Layername:
l2g
File name:
sierra.group7.gbr
X:
8.8313
Y:
4.4200
Refdes:
 
Value Found:
7.500
Rule:
9.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
PTH to Copper
Comment: When a plated hole is too close to copper features the plated hole may short to the copper feature. The plated hole to copper feature minimum requirement for this product is 9.800 mils. This location measures 7.500 mils.
There are 20 additional locations where this issue occurs...
Click Thumbnail on Right to see locations.
Layername:
l2g
File name:
sierra.group7.gbr
X:
2.1535
Y:
2.7650
Refdes:
 
Value Found:
8.000
Rule:
9.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
PTH to Copper
Comment: When a plated hole is too close to copper features the plated hole may short to the copper feature. The plated hole to copper feature minimum requirement for this product is 9.800 mils. This location measures 8.000 mils.
There are 5 additional locations where this issue occurs...
Click Thumbnail on Right to see locations.
Layername:
l2g
File name:
sierra.group7.gbr
X:
10.6892
Y:
3.9253
Refdes:
 
Value Found:
8.476
Rule:
9.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
PTH to Copper
Comment: When a plated hole is too close to copper features the plated hole may short to the copper feature. The plated hole to copper feature minimum requirement for this product is 9.800 mils. This location measures 8.476 mils.
There are 12 additional locations where this issue occurs...
Click Thumbnail on Right to see locations.
Layername:
l2g
File name:
sierra.group7.gbr
X:
10.6167
Y:
4.2650
Refdes:
 
Value Found:
8.500
Rule:
9.800
Cad Names:
Not Available
Sync Files Available:
None
Title:
PTH to Copper
Comment: When a plated hole is too close to copper features the plated hole may short to the copper feature. The plated hole to copper feature minimum requirement for this product is 9.800 mils. This location measures 8.500 mils.
There are 122 additional locations where this issue occurs...
Click Thumbnail on Right to see locations.
Created by, Direct Logix; © Copyright 2002-2007, All Rights Reserved.